Ohmsums

Capacitor code calculator

Ceramic and film capacitor markings to pF, nF and µF, and a value back to its code. Results update as you type.

Indicative calculation; verify before use.

Code to value

Examples: 104, 473K, 4R7, 47, 2A104J, 1H222K, 105K 250V, 4n7.

–
Picofarad
–
Nanofarad
–
Microfarad
–
Tolerance
–
Voltage
–

Value to code

Code
–

Below 10 pF the code uses R as the decimal point (4R7 = 4.7 pF). The three-digit code holds two significant digits, so values are rounded.

Common codes

Tap a code to decode it above.

CodepFnFµF
1 pF0.001 nF0.000001 µF
2.2 pF0.0022 nF0.0000022 µF
4.7 pF0.0047 nF0.0000047 µF
10 pF0.01 nF0.00001 µF
22 pF0.022 nF0.000022 µF
47 pF0.047 nF0.000047 µF
100 pF0.1 nF0.0001 µF
220 pF0.22 nF0.00022 µF
470 pF0.47 nF0.00047 µF
1000 pF1 nF0.001 µF
2200 pF2.2 nF0.0022 µF
4700 pF4.7 nF0.0047 µF
10000 pF10 nF0.01 µF
22000 pF22 nF0.022 µF
47000 pF47 nF0.047 µF
100000 pF100 nF0.1 µF
220000 pF220 nF0.22 µF
470000 pF470 nF0.47 µF
1000000 pF1000 nF1 µF
10000000 pF10000 nF10 µF

How it works

Code XYZ → C = XY × 10^Z pF Z = 8 → × 0.01, Z = 9 → × 0.1 4R7 → 4.7 pF (R marks the decimal point) 1 nF = 1000 pF, 1 µF = 1000 nF

The first two digits are the significant figures and the third is the number of zeros, in picofarads: 104 is 10 followed by four zeros = 100 000 pF = 100 nF. One- and two-digit markings (47) are plain picofarads. Some parts use a unit letter as the decimal point instead (4n7 = 4.7 nF, 1u0 = 1 µF).

A letter after the code is the tolerance: F ±1 %, G ±2 %, J ±5 %, K ±10 %, M ±20 %, Z +80 % / −20 %. For values below 10 pF, B, C, D, F and G mean ±0.1, ±0.25, ±0.5, ±1 and ±2 pF. A digit and a letter before the code is the voltage rating, for example 1H = 50 V and 2A = 100 V. Supported voltage codes: 0G 4 V, 0J 6.3 V, 1A 10 V, 1C 16 V, 1E 25 V, 1H 50 V, 1J 63 V, 2A 100 V, 2D 200 V, 2E 250 V, 2F 315 V, 2G 400 V. Many parts write the voltage out (100V) instead.

A third digit of 9 or 8 is read as × 0.1 or × 0.01 (109 = 1 pF, 108 = 0.1 pF). Some manufacturers use this; we could not confirm it in the sources below, so treat such readings with extra care.

Markings are not fully standardised across manufacturers. Check the datasheet when a part matters, and measure unknown parts.

Sources (checked 2026-10-31):